Operation
8 3A1215C
Marker Layout Mode
Change Value
Set space sizes up to 8 consecutive measurements. By leav-
ing zeros in any space, Marker Layout Mode will skip to the
next measurement in a continuous loop.
DOT Size (sec)
The amount of time the gun will be activated.
NOTE: Lowering system pressure may help produce smaller
more precise DOTS.
Marker Layout Mode Example:
Diagnostics
 
  
  
  
  
  
  
  












ti16379a
NOTE: To operate Marker Layout Mode, you must be in the Marker Layout Mode Menu.
Choose a spray gun and toggle that switch to the skipline setting.
 
  
  
  
  
  
  
  






1. Set space sizes.
2. Select DOT SIZE (amount of time gun activates).
3. Select one or more guns in skip line.
4. Activate with HOLD/RESET switch.
48.00 ft
16.00 ft
8.00 ft4.00 ft 4.00 ft8.00 ft
4.00 ft 4.00 ft
ti16733a
Diagnostics
gun safety ON OFF
B
Exit
ROADLAZER ROADPAK
ROADLAZER TOW BEHIND
Distance 0
Pump 1 0
Pump 2 0
Pump 3 0
A
Reset
counters
SOLENOIDS
12345 6
SWITCH TEST
CAUTION
SOLENOIDS WILL
STILL ACTUATE
123
BEADS ON
BEAD TEST
ADV
RET
RESET
HOLD
Diagnostics
B
Exit
Distance 0
Pump 1 0
Pump 2 0
A
Reset
counters
SOLENOIDS
12345 6
SWITCH TEST
CAUTION
SOLENOIDS WILL
STILL ACTUATE
123
BEADS ON
BEAD TEST
ADV
RET
RESET
HOLD
This menu is used to verify inputs from control box switches and sensors on the sys-
tem, as well as to check if the solenoids are functioning properly. NOTE: Solenoid
will still be active during the test, which could result in turning the paint and bead
guns ON and OFF.
Distance - Counts 50 +/- 2 pulses per revolution of the wheel. Input can be checked
by spinning the RoadPak gun arm wheel.
Pump 1 and Pump 2 - Counts one pulse per complete cycle/stroke.
Switches: The darkened box indicates the position of the switch. Toggle each switch
individually and the darkened box should move to the new location if functioning
properly. If the darkened box does not move, the switch is not functioning properly
and will most likely need to be replaced.
Solenoids - Checks for presence of solenoid valve in system. A darkened box indi-
cates solenoid is recognized by the control box. Solenoids will not be recognized with
gun arm in up position when mechanical safety switch is used. Solenoid bank will not
appear if power is not present.