Graco 3A1215C Manual do Utilizador Página 6

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 5
Operation
6 3A1215C
Distance Calibration
The Distance Calibration Menu is used to calibrate the
system against a measured distance (see Distance
Calibration Procedure, page 9).
1. Use adjacent arrows to enter the length of the mea-
sured course.
2. Press at the beginning of the measured
course.
3. Press at the end of the measured course.
NOTE: Distance accuracy is based on calibration. Use a
good quality measuring tape.
Pump Calibration
The Pump Calibration Menu is used to adjust the unit of
measurement for accurate material usage in gallons or
liters.
1. Press to toggle between units for display mea-
surements.
2. Use adjacent arrows to change pump cycles per
unit volume (RPS 2900 preset value is 14.9, Road-
Lazer Tow Behind is 37. Value may need adjusting
due to viscosity of material)
Set Gun Delays
The Set Gun Delays Menu is used to synchronize paint
and bead guns in inches (cm). Incrementing value is
based on the resolution of the distance sensor.
NOTE: In the event of no distance travel sensing the
guns will default to a 1 second delay.
NOTE: Follow on-screen instructions.
1. Press to switch between Bead Gun and Paint
Gun.
2. Use adjacent arrows to change ON/OFF Delay
Distance.







 


ti16376a


 







ti16381a

 
 







