Graco 313386D Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para não Graco 313386D. Graco 313386D User's Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 42
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
313386D
EN
Software Instructions
ProMix
®
2KS/3KS Web
Interfaces
Installation and program setup instructions to allow communication between a PC and the
ProMix
®
2KS/3KS Electronic Proportioner, via an Ethernet. For professional use only.
Not for use in explosive atmospheres.
Basic Web Interface (supplied with ProMix 2KS/3KS EasyKey software)
Advanced Web Interface Kit 15V337 (Accessory)
Important Safety Instructions
Read all warnings and instructions in this manual
and in your proportioning system manual. Save
these instructions.
TI12933b
Advanced Web Interface Module Shown
Vista de página 0
1 2 3 4 5 6 ... 41 42

Resumo do Conteúdo

Página 1 - Interfaces

313386DENSoftware InstructionsProMix® 2KS/3KS Web Interfaces Installation and program setup instructions to allow communication between a PC and the P

Página 2 - Related Manuals

ProMix 2KS/3KS Basic Web Interface (BWI) 10 313386DReportsNOTE: Display material usage report - shows the material sprayed from the ProMix 2KS/3KS. Se

Página 3 - Warnings

ProMix 2KS/3KS Basic Web Interface (BWI)313386D 11Display job log - displays the job number, date, time, recipe, ratio, target, volumes, grand totals,

Página 4 - Installation

Install the Advanced Web Interface (AWI) Module 12 313386DInstall the Advanced Web Interface (AWI) ModuleOverviewThe Graco Advanced Web Interface (AWI

Página 5 - 313386D 5

Install the Advanced Web Interface (AWI) Module313386D 13Connect Module to EasyKey and PC1. Shut off ProMix 2KS/3KS power (0 position). FIG. 23. Also

Página 6 - 6 313386D

Install the Advanced Web Interface (AWI) Module 14 313386DFIG. 25: ProMix Network Typical InstallationTI13065aEasyKeysAWI Master ModuleComputerUse CAT

Página 7 - 313386D 7

Install the Advanced Web Interface (AWI) Module313386D 15FIG. 26: LAN Network (Manual) Typical InstallationTI13064bEasyKey EasyKeyLAN NetworkAWI Modul

Página 8 - Web Navigation Screens

Computer Configuration 16 313386DComputer ConfigurationSet up an Automatic IP AddressSee FIG. 27. On your computer, go to Control Panel>Network Con

Página 9 - Software/Resets

Computer Configuration313386D 174. The Welcome screen will appear. See FIG. 29. Click Next.5. The Security screen will appear. See FIG. 30. The admini

Página 10 - 10 313386D

Computer Configuration 18 313386DPassword Recovery1. If you type in the wrong password, sign in will be blocked. See FIG. 33. Click on the block icon

Página 11 - 313386D 11

Computer Configuration313386D 19Set the Network ConfigurationProMix 2KS/3KS Network ConfigurationIn a ProMix 2KS/3KS network, the AWI module is con-ne

Página 12 - Mounting

Related Manuals 2 313386DContentsRelated Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Warnings . . . . . . . . . . . . . . . . .

Página 13 - 313386D 13

Computer Configuration 20 313386DLAN Network (Manual) ConfigurationSee FIG. 26. A LAN network (manual) configuration enables you to work through a loc

Página 14 - 14 313386D

AWI Screens313386D 21AWI ScreensThis section describes how to use the AWI screens to access and make changes to system settings and reci-pes. For comp

Página 15 - 313386D 15

AWI Screens 22 313386DMaterials TabUse the Materials tab to enter information on Volatile Components (VOC) and Hazardous Air Pollutants (HAP) for each

Página 17 - 313386D 17

AWI Screens 24 313386DSettings TabUse the Settings tab to configure the main system set-tings (Time, Language, Upgrade AWI, and Edit Accounts). NOTE:

Página 18 - Password Recovery

AWI Screens313386D 25Edit Account InformationNOTE: Account information can only be entered by a system administrator. See FIG. 42.• To add a new accou

Página 19 - Set the Network Configuration

AWI Screens 26 313386DSystem Setup ScreensTo view the system setup screens, go to the Network tab and click on the desired EasyKey to access the setup

Página 20 - 20 313386D

AWI Screens313386D 27Material Setup TabGo to the Material Setup tab to assign a catalyst, color, reducer (on 3KS) and flush material for the valves of

Página 21 - AWI Screens

AWI Screens 28 313386DSystem Setup TabThe Setup tab has three editable screens:•The Configuration screen corresponds to the Sys-tem Configuration scre

Página 22 - Materials Tab

AWI Screens313386D 29FIG. 47. System Setup Tab, Advanced ScreenFIG. 48. System Setup Tab, Recipe ScreenClick to create a recipe timing chart. See FIG.

Página 23 - 313386D 23

Warnings313386D 3WarningsThe following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-tion point s

Página 24 - Settings Tab

AWI Screens 30 313386DFIG. 49. Sample Recipe Timing Chart

Página 25 - button

AWI Screens313386D 31Reports TabThe Reports tab enables you to produce three reports:• Material Report•Job Report• Alarm ReportSelect which of the thr

Página 26 - System Setup Screens

AWI Screens 32 313386DJob ReportSee FIG. 51. The Job Report provides detailed informa-tion on all completed jobs within a designated time period. Sele

Página 27 - Material Setup Tab

AWI Screens313386D 33Alarm ReportSee FIG. 52. The Alarm Report lists all alarms triggered within a designated time period. Set the time frame by using

Página 28 - to create a

AWI Screens 34 313386DLevel Control TabSee FIG. 53. The Level Control Tab allows you to input the supply tank volume of the materials and the level at

Página 29 - 313386D 29

AWI Screens313386D 35SidebarSee FIG. 54. The Sidebar relates to the EasyKey being monitored. It has four links to related screens: • Save - saves the

Página 30 - 30 313386D

Replace AWI Board 36 313386DReplace AWI Board1. Shut off ProMix 2KS/3KS power (0 position). 2. Shut off power at main circuit breaker.3. Open the AWI

Página 31 - to begin a new report

Replace AWI Board313386D 37

Página 32 - 32 313386D

Parts 38 313386DParts15V337 Advanced Web Interface ModuleParts labeled n/a are not available separately.TI12926aTI12927aTI12928a3456810111213415171817

Página 33 - 313386D 33

Parts313386D 3915V336 Advanced Web Interface Server HubParts labeled n/a are not available separately.+24COMV1+V1-TI13204aTI13206aTI13205a345681011121

Página 34 - Level Control Tab

ProMix 2KS/3KS Basic Web Interface (BWI) 4 313386DProMix 2KS/3KS Basic Web Interface (BWI)NOTE: Screen views in this manual are shown using Microsoft

Página 35 - 313386D 35

Electrical Schematic 40 313386DElectrical SchematicNon-Hazardous AreaDISPLAYBOARD 1234 J91234567891011J41234567891011121314151617181920DISPLAYMEMBRANE

Página 36 - Replace AWI Board

Dimensions313386D 41DimensionsTI12825b16.57 in. (420.9 mm)15.07 in. (382.8 mm)6.45 in. (163.8 mm)5.31in. (134.9 mm)8.71in. (221.2 mm)TI12926a

Página 37 - 313386D 37

All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves th

Página 38 - TI12928a

ProMix 2KS/3KS Basic Web Interface (BWI)313386D 53. Before running the BWI software you must manually assign an IP address to your computer:a. On your

Página 39 - 313386D 39

ProMix 2KS/3KS Basic Web Interface (BWI) 6 313386Dc. In the Local Area Connection Properties win-dow, scroll to Internet Protocol (TCP/IP) and double

Página 40 - Electrical Schematic

ProMix 2KS/3KS Basic Web Interface (BWI)313386D 74. On the EasyKey, go to System Configuration Screen 5 and write down the IP number assigned to that

Página 41 - Dimensions

ProMix 2KS/3KS Basic Web Interface (BWI) 8 313386DWeb Navigation ScreensFrom the main BWI screen (see FIG. 7) the operator can select Setup, Software/

Página 42 - Graco Information

ProMix 2KS/3KS Basic Web Interface (BWI)313386D 9Download custom language - saves the current system language to the PC. See FIG. 10. This file is ope

Comentários a estes Manuais

Sem comentários