3082246
List of Models
Pressure and Ratio Ratings for President Pumps
WARNING
To reduce the risk of over pressurizing a component, which can result in an explosion and serious injury, never
operate the system at a working pressure higher than the lowest rated component in the system. All fluid side
components such as dispensing valves, regulators, and hoses must have a working pressure equal to or greater
than the pressure given in Column B for each pump model.
Column A gives the maximum fluid pressure developed at 100 psi (0.7 MPa, 7 bar) of incoming air pressure.
Column B gives the minimum working pressure required for all system components, based on the automatic
relief valve settings. Components included by Graco with the models listed meet or exceed this requirement.
Models with Two Displacement Pumps
A B
Model No.
Maximum Pump
Fluid Pressure
at 100 psi (7 bar) Air
Minimum
Component
Working Pressure
Normal
Pressure
Ratio
Nominal Flow
Volume
@ 40 cpm
Mix Ratio
Bare Wall Stand psi bar psi bar
(Fluid to Air)
gpm lpm
1:1 231643** 231593** 231618** 1280 89 1800 124 12.80 1.5 5.7
1:1 231644 1601 112 1800 124 16.01 1.2 4.5
1:1 231645** 231595** 1921 135 2300 159 19.21 1.0 3.8
1:1 231646** 2561 179 2900 200 25.61 0.75 2.8
** CE approved and certified.